BỘ LƯU ĐIỆN OLS2000EXL

Mã sản phẩm: OLS2000EXL

 

- Công nghệ:  ONLINE
- Công xuất : 2000VA/1600W
- Điện áp vào: 220 VAC
- Tần số nguồn vào: 40 – 70 Hz
- Điện áp ra: 208/220/230/240VAC
- Tần số nguồn ra: 50/60Hz ± 0.5%
- Thời gian chuyển: 0 ms
- Thời gian sạc : phụ thuộc vào pin bên ngoài
- Phụ kiện: User manual
- Thời gian back-up (full) : phụ thuộc vào pin bên ngoài

Liên hệ

Giao hàng toàn quốc

Thanh toán khi nhận hàng

Hoàn 100% tiền nếu hàng không đúng như web

Model OLS2000EXL
Capacity(VA/W) 2000VA / 1600W
Typology Online (Double Conversion)
Energy-Saving Technology Yes, ECO Mode Efficiency > 95%
Input
Voltage Range 120~139Vac for 0~25% Load
140~159Vac for 0~50% Load
160~179Vac for 0~75% Load
180~280Vac for 0~100% Load
Input Type IEC C20
Frequency Range 40~70Hz
Output
UPS Outlets (Numbers) (4) IEC C13 + Terminal Block
On Battery Output Voltage Pure Sine Wave at 208, 220, 230, 240 Vac (Configurable)
On Battery Output Voltage Distortion (@Nominal Battery Voltage) ≦3%(Linear Load), ≦5%(Non-Linear Load)
On Battery Output Frequency 50 Hz / 60 Hz (Auto-Sensing or Configurable) ± 0.5%
Transfer Time (Typical) 0ms
Overload Protection AC Mode: Warning only @ 110%>Load>105%,
Transfer to bypass after 60sec @ 120%>Load>110%,
Transfer to bypass immediately@ Load>120% Battery Mode: Warning only @ 110%>Load>105%,
Shutdown after 10sec @ 120%>Load>110%,
Shutdown immediately @ Load>120%
Bypass Mode: Warning only @ 130%>Load>105%,
Shutdown immediately @ Load>130%
Surge Protection and Filtering
Surge Protection Yes
DSL/Phone/Fax/Modem protection RJ11/RJ45(One In/One Out)
Short Circuit Protection UPS Output Cut off Immediately or Circuit Breaker Protection
Physical
Dimensions(H x W x D)(mm) 337 x 196 x 416
Weight(kg) 12.2
Battery
Sealed Maintenance Free Lead Acid Battery Depends on external batteries
Configurable External Battery Pack (Max.) 10
Typical Recharge Time Depends on external batteries. Built-in Charger (8A Max. )
Runtimes
Half load-Full load (mins) Depends on external batteries
Status Indication
Indicators Power On, Line Mode, Battery Mode, Bypass Mode, ECO Mode,C/F Mode, Fault, Replace Battery
Audible Alarms Battery Mode, Battery Low, Overload, UPS Fault, Replace Battery
Communication
Power Management Software PowerPanel® Business Edition
Management
Self-Test Yes
Auto-Charge/Auto-Restart Yes
Auto-Overload Recovery Yes
Cold Start(DC Start) Yes
Connectivity Ports (1) Serial Port (RS232), (1) USB Port, (1) EPO/ROO
SNMP/HTTP Capable Optional
#All specifications are subject to change without notice.